When process equipment repeatedly heats and cools, an O-ring that retains more recovery space after release is better positioned to keep contacting the groove and mating surface. The official page for the M-FFKM-02 perfluoroelastomer O-ring lists a 320°C temperature rating and ASTM D395 compression-set results, giving engineers condition-specific evidence rather than a material name alone.
Recovery after heat supports continued contact
The product page reports ASTM D395 compression set of 13% after 70 hours at 200°C and 20% after 70 hours at 300°C. A lower compression-set result means the specimen recovered more of its original thickness under the stated conditions. This is useful evidence for static-seal selection, but it is not a guarantee of equipment life or leakage performance.
FFKM addresses heat and chemical exposure together
The official page identifies M-FFKM-02 as a perfluoroelastomer and lists semiconductor processing, chemical equipment, and high-temperature vacuum equipment as application directions. For civilian process equipment facing both heat and media exposure, the FFKM O-ring specifications and test conditions provide a starting point; compatibility with the actual medium still requires confirmation.
Hardness and strength make assembly discussions concrete
The product page lists 75 Shore A hardness, 17.77 MPa tensile strength, and 135.3% elongation at break, with ASTM D2240 and ASTM D412 identified as the respective methods. These values help frame groove, squeeze, and installation discussions, but they do not replace finished-part tolerances, surface condition, and medium-specific validation.
Why compression set matters
ASTM D395 describes compression-set testing as a way to measure how rubber retains elastic properties after prolonged static compression. For constant deflection, the concept is CS = (t0 – t1) / (t0 – ts) × 100%, where CS is compression set, t0 is original thickness, t1 is thickness after release and the prescribed recovery period, and ts is spacer thickness; thickness values are in mm. Results are comparable only when specimen geometry, deflection, temperature, time, medium, and recovery procedure match. The equation alone cannot predict O-ring life, leakage rate, or dynamic-seal behavior.
Bring the specification back to the groove
For a sample or specification review, provide the medium, continuous and peak temperatures, pressure, groove dimensions, O-ring cross-section, static or dynamic duty, and cleanliness requirements. Lixing Composite Materials Co., Ltd. can review these conditions with the available product data; the website does not offer online checkout.
#FFKM #ORing #HighTemperatureSeal #CompressionSet