When a thermal module has a measurable gap, limited mounting pressure or a need for a fixed die-cut shape, a soft compressible thermal gap pad can create a more controllable path between the heat source and housing. Lixing offers 5 to 40 Shore B hardness and 0.25 mm to 1.3 mm thickness options for CPU, GPU, power and 5G equipment, so engineers can start with the assembly conditions before comparing grease or gel.
A defined gap favours a material with defined placement
A pad occupies the space between a heat source and thermal module as a solid sheet. It can be die-cut to a drawing, with size, shape and surface tack adjusted for the assembly. This form suits applications that need positioning, repeatable placement or reduced material migration. The Lixing thermal gap pad product page lists thicknesses from 0.25 mm to 1.3 mm, die cutting and roll supply.
At low pressure, conformability belongs in the decision
The product hardness range is 5 to 40 Shore B, allowing the pad to conform to uneven surfaces under relatively low pressure. Conductivity grades span 1.0 to 10.0 W/m·K. For flexible thermal pad selection, confirm gap, allowable pressure and contact area first, then choose a suitable thickness and k grade from the same thermal pad family.
Grease and gel fit thin interfaces, with separate process checks
Grease is commonly considered for a very thin contact interface, while gel can suit dispensing processes and irregular spaces. Their installed performance depends on dispensing volume, bond-line thickness, voids and thermal cycling. The product page does not provide a comparative test of all three forms, so this article does not claim that one form always produces lower resistance. Samples should be evaluated under the same pressure and heat-flow conditions.
Engineering check: R = L / (kA)
MIT thermal-resistance notes express plane-wall bulk resistance as R = L / (kA). R is thermal resistance in K/W, L is thickness along heat flow in m, k is thermal conductivity in W/(m·K), and A is effective area normal to heat flow in m². At the same area, greater thickness raises bulk resistance and higher k lowers it. The model assumes steady one-dimensional heat flow, near-constant conductivity and no internal heat generation. It excludes two-sided contact resistance, roughness, compression, voids, ageing and pump-out, so it is neither a product test nor a lifetime guarantee.
Send gap, pressure and dimensions with the sample request
Useful sample inputs include heat-source and sink dimensions, nominal gap and tolerance, fastening method, allowable pressure, operating temperature, insulation needs, target conductivity grade and the die-cut drawing. The product page also lists a -40°C to 200°C temperature range and UL 94 V-0 / V-1 flame ratings. Confirm the selected grade and test conditions before use.
Match the material form to the thermal module
Where CPU, GPU, power-supply or 5G heat paths combine a gap, low pressure and placement requirements, a soft pad can bring fit and assembly control into one part. Review the official product options, then measure interface temperature and installed condition with the intended assembly.